Gurit Corecell Structural Core-Bonding Syntactic Putty vs. Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat
Gurit Corecell Structural Core-Bonding Syntactic Putty (Gurit Composite Materials) and Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat (Polynt Composites USA) achieve a 82% ASTM engineering compatibility score in Marine ISO/NPG Gelcoats, Structural Bonding Pastes & Mold Releases. Tensile strength delta is -48 MPa (-64.9%) and thermal HDT delta is +4 °C, making them interchangeable with post-cure temperature and viscosity flow adjustments.
Side-by-Side ASTM Mechanical, Thermal, Rheological & Pricing Delta
| ASTM Parameter | A: Gurit Corecell Structural Core-Bonding Syntactic Putty (Gurit Composite Materials) | B: Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat (Polynt Composites USA) | Engineering Delta (A vs. B) |
|---|---|---|---|
| OEM Manufacturer & SKU | Gurit Composite Materials • GUR-COREBOND-20K | Polynt Composites USA • POL-ARM950-DR | Cross-Brand OEM Equivalent |
| ASTM D638 Tensile Strength (MPa / PSI) | 26 MPa (3,771 psi) | 74 MPa (10,733 psi) | -48 MPa (-64.9 %) |
| ASTM D648 Heat Deflection Temp (HDT °C / °F) | 86 °C (187 °F) | 82 °C (180 °F) | +4 °C (Direct Thermal Match) |
| ASTM D790 Flexural Strength (MPa) | 37.7 MPa | 92 MPa | -54.3 MPa (-59 %) |
| ASTM D2583 Barcol Hardness | 38 | 40 | -2 Barcol |
| ASTM D2196 Brookfield Viscosity @ 25°C | 180000 cPs | 15500 cPs | +164500 cPs (+1061.3 %) |
| Gel Time @ 25°C (Minutes) | 30 min | 20 min | +10 min |
| ASTM D792 Specific Density (kg/m³) | 1140 kg/m³ | 1120 kg/m³ | +20 kg/m³ |
| US DOT 49 CFR & TDG Hazmat Class | Class 3 Flammable Liquid (UN1866) | Class 3 Flammable Liquid (UN1866) | Identical (UN1866) |
| Unit Price ($/kg USD) & Pack Price | $15.8/kg • $284 (20 kg Pail) | $11.2/kg • $224 (19 L Industrial Pail) | +4.6 $/kg (+41.1 %) |
| Marine & Aerospace Type Approvals | Direct Class Match | ||
| US Stocking Warehouses | Danvers, MA • Tampa, FL • Houston, TX • Mira Loma, CA | Hickory, NC • Danvers, MA • Tampa, FL | 1–3 Days LTL Dispatch |
Configure Complete Cure, Structural Adhesive & Bagging BOM — Request Regional Distributor Quote
Both matrices cross-link via free-radical polymerization using 1.25%–2.0% MEKP (Methyl Ethyl Ketone Peroxide, UN3105) or Cumene Hydroperoxide (CHP) with Cobalt Octoate promoter. Low-hydrogen-peroxide MEKP (e.g., Norox MEKP-925H) is recommended to eliminate micro-foaming.
Direct Drop-In Qualified: Thermal deflection (ASTM D648 HDT) differs by only 4 °C (86 °C vs. 82 °C). Existing mold cure and demold cycles can be maintained without thermal schedule modification.
Identical Hazmat Logistics Profile: Both SKUs ship under US DOT 49 CFR & Transport Canada TDG as Class 3 Flammable Liquid (UN Number: UN1866). Note 49 CFR § 177.848 segregation if ordering with Class 5.2 Organic Peroxides (UN3105).
Engineering FAQ: Gurit Corecell Structural Core-Bonding Syntactic Putty vs. Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat
1. Is Gurit Corecell Structural Core-Bonding Syntactic Putty a direct drop-in equivalent for Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat?▼
Gurit Corecell Structural Core-Bonding Syntactic Putty (Gurit Composite Materials) and Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat (Polynt Composites USA) achieve a 82% ASTM engineering compatibility score in Marine ISO/NPG Gelcoats, Structural Bonding Pastes & Mold Releases. Tensile strength delta is -48 MPa (-64.9%) and thermal HDT delta is +4 °C, making them interchangeable with post-cure temperature and viscosity flow adjustments.
2. What is the ASTM D638 Tensile Strength and ASTM D648 HDT difference between Gurit Corecell Structural Core-Bonding Syntactic Putty and Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat?▼
Gurit Corecell Structural Core-Bonding Syntactic Putty (Gurit Composite Materials) delivers ASTM D638 Tensile Strength of 26 MPa (3,771 psi) and ASTM D648 HDT of 86 °C, whereas Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat (Polynt Composites USA) delivers 74 MPa (10,733 psi) and HDT of 82 °C. The net delta is -48 MPa (-64.9 %) tensile and +4 °C HDT.
3. Do Gurit Corecell Structural Core-Bonding Syntactic Putty and Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat use the same catalyst or hardener cure system?▼
Both matrices cross-link via free-radical polymerization using 1.25%–2.0% MEKP (Methyl Ethyl Ketone Peroxide, UN3105) or Cumene Hydroperoxide (CHP) with Cobalt Octoate promoter. Low-hydrogen-peroxide MEKP (e.g., Norox MEKP-925H) is recommended to eliminate micro-foaming. Direct Drop-In Qualified: Thermal deflection (ASTM D648 HDT) differs by only 4 °C (86 °C vs. 82 °C). Existing mold cure and demold cycles can be maintained without thermal schedule modification.
4. How do US DOT 49 CFR Hazmat shipping rules and B2B drum/pack prices compare between Gurit Corecell Structural Core-Bonding Syntactic Putty and Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat?▼
Identical Hazmat Logistics Profile: Both SKUs ship under US DOT 49 CFR & Transport Canada TDG as Class 3 Flammable Liquid (UN Number: UN1866). Note 49 CFR § 177.848 segregation if ordering with Class 5.2 Organic Peroxides (UN3105). In US B2B distribution, Gurit Corecell Structural Core-Bonding Syntactic Putty is priced at $284 per 20 kg Pail ($15.8/kg) vs. $224 per 19 L Industrial Pail ($11.2/kg) for Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat (delta: +4.6 USD/kg).
Related Drop-In Comparisons in Marine ISO/NPG Gelcoats, Structural Bonding Pastes & Mold Releases
Gurit Corecell Structural Core-Bonding Syntactic Putty (Gurit Composite Materials) and Polynt Armorcote 950 High-UV Marine ISO/NPG Gelcoat (Polynt Composites USA) are trademarks of their respective owners. AvailAgent LLC (dba CompositeMatrix™) is an independent North American B2B composite material intelligence registry; comparative ASTM D638, D648, D790, D2583, and D2196 figures are presented under the US legal doctrine of Nominative Fair Use (Lanham Act, 15 U.S.C. § 1125) and Feist Publications, Inc. v. Rural Telephone Service Co. (499 U.S. 340) for scientific and industrial cross-reference. Cure schedules, exotherm behavior, and laminate qualification must be verified by a licensed Naval Architect or Professional Engineer (PE) against current manufacturer batch Technical Data Sheets (TDS) and Safety Data Sheets (SDS).